CipherLab Co. Ltd. 1660 User Manual
138
Enter Setup
1600 Series Barcode Scanner
User Guide
4) Run the download utility “ProLoad.exe” or “Download.exe” on your computer.
(Download.exe requires version 2.3 or later!)
Open the firmware update “*.shx”, and select the correct COM port.
Baud rate
– 115,200 bps
Data bit
– 8
Parity
– None
Flow control – None
5) The scanner will automatically restart itself when upgrading firmware is completed
successfully.
Enter Setup
Download