The Watt Stopper Inc. EOPC-100 User Manual

Page of 5
Quick Start Guide
SENSOR PLACEMENT (12’ MAX. HEIGHT)
PAIRING OF SENSOR TO RECEIVER LOAD(S)
,WLVUHFRPPHQGHGWKDWSDLULQJRIGHYLFHVEHGRQHSULRUWR
LQVWDOOLQJFHLOLQJVHQVRU
Step 1: Enter Pairing Mode
Press and Hold “Pairing” Button on 
Receiver for 3 Seconds then release:
âÝ3DLULQJÞ/('EOLQNVWLPHV 
VHFRQGWRFRQILUPSDLULQJPRGH
 
 For EOSW-101
 
âLoad 1 turns ONDQGLVUHDG\ 
WREHSDLUHG
 
â%XWWRQ/('LV6ROLG
ON
 
For EOSW-102
 
â/RDG WXUQ
ON and are 
UHDG\WREHSDLUHG
 
â%XWWRQ /('DUH6ROLG
ON
Step 2: Selecting a Specific Load to Pair 
(EOSW-102)
,IERWKORDGVDUHWREHFRQWUROOHGE\
2FFXSDQF\6HQVRUWKDQVNLSWKLVVWHS
Tap the “Pairing” button once 
while in pairing mode:
â/RDGWXUQV
OFF and Load 1 
UHPDLQV
ON
â/RDGLVQRZDFWLYHDQG
UHDG\WREHSDLUHGWRVHOHFWHG
WUDQVPLWWHUV
â/RDG/('LV6ROLG
ON
Tap the “Pairing” button once 
again while in pairing mode:
â/RDGWXUQV
OFF and Load 2 
      turns ON
â/RDGLVQRZDFWLYHDQG
UHDG\WREHSDLUHGWRVHOHFWHG
WUDQVPLWWHUV
â/RDG/('LV6ROLG
ON 
Tap the “Pairing” button a thrid time while in pairing 
mode:
â/RDGDQG/RDGWXUQ
ONDJDLQ
EOPC-100
Wireless Lighting Control System
Wireless Self-Powered PIR Ceiling Mount  
 Extended Range Occupancy Sensor
Sensor
28'
30'
COVERAGE PATTERN
7KH(23&SURYLGHVDr
FRYHUDJHSDWWHUQ7KHFRYHUDJH
VKRZQUHSUHVHQWVPD[LPXP
FRYHUDJHIRUZDONLQJPRWLRQDW
DPRXQWLQJKHLJKWRIIHHW
Strong air
supply
6’
Sensor
Mount sensor at least 6’ away from hot air supply.
Avoid obstacles that block sensor’s line-of-sight.
Pendant
fixture
,QSXW9ROWDJH .............................6HOI3RZHUHG2SWLRQDO%DWWHU\
2SHUDWLQJ/LIHDW)XOO&KDUJH ............................................ 72 hrs
&RQQHFWLRQWR:LUHOHVV1HWZRUN.......... 7UDQVPLWVVLJQDOWR:DOO 
6ZLWFK5HFHLYHU(26:YLD5DGLR)UHTXHQF\
(QYLURQPHQW ................................................. )RU,QGRRU8VH2QO\
 2SHUDWLQJ7HPSHUDWXUH ....................rWRr)rWRr&
 6WRUDJH7HPSHUDWXUH ...................... rWRr)rWRr&
 5HODWLYH+XPLGLW\ ...........................WRQRQFRQGHQVLQJ
3DWHQW3HQGLQJ
44 ft
Extended Range Lens (Standard) 
EOPC-100
8 ft
22 ft
13 ft
7 ft 3 ft 0 3 ft 7 ft
13 ft
22 ft
Typical
desk-top
level
EOSW-101 Series
T
P
O
C
“Load Status”
Blue LED 
Pairing
Button
 
MAJOR MOTION
 
Ideal: 44ft diameter @8ft 
Minimum: 35ft diameter @ 8ft
MINOR MOTION
 
Ideal: 30ft diameter @8ft 
Minimum: 25ft diameter @ 8ft
EOSW-102 Series
T
P
O
C
“Load 1 Status”
Blue LED Off
Pairing
Button
 
“Load 2 Status”
Blue LED On 
EOSW-102 Series
T
P
O
C
“Load 1 Status”
Blue LED ON 
Pairing
Button
 
EOSW-102 Series
T
P
O
C
“Load Status”
Blue LEDs 
Pairing
Button
 
 
WarningDo Not Mount in a dark room (< 3 fc). 
If necessary, please insert optional battery.