Thermal Specifications
Unlike MbxSend(), no Assured Write protocol is necessary for this command because 
this is a read-only function.
7.3.2.8.2
Command Format
The MbxGet() format is as follows:
Write Length: 2
Read Length: 5
Command: 0xd5
Multi-Domain Support: Yes (see 
Description: Retrieves response data from mailbox and unlocks / releases that 
mailbox resource.
Note that the 4-byte data response defined above is sent in standard PECI ordering 
with LSB first and MSB last.
Figure 7-30. MbxGet()
 Response Data[31:0]
Byte #
Byte 
Definition
0
Client Address
1
Write Length
0x02
2
Read Length
0x05
10
FCS
3
Cmd Code
0xd5
11
Completion
Code
5
6
LSB
MSB
5
6
4
Transaction ID
10
11
5
6
8
9
7
10
FCS
11
Table 7-30. MbxGet() Response Definition (Sheet 1 of 2)
Response
Meaning
Aborted Write FCS Response data is not ready. Command retry is appropriate.
 0x40
Command passed, data is valid
 0x80
Error causing a response timeout. Either due to a rare, internal timing condition or a 
processor RESET condition or processor S1 state. Retry is appropriate outside of the 
RESET or S1 states.
 0x81
Thermal configuration data was malformed or exceeded limits.
 0x82
Thermal status mask is illegal
 0x83
Invalid counter select
 0x84
Invalid Machine Check Bank or Index
0x85
Failure due to lack of Mailbox lock or invalid Transaction ID
0x86
Mailbox interface is unavailable or busy