NOTE – Verify that each unit has a different unit ID 
 
 
NOTE – In a Mobile MESH network configuration, the Number of Hops and 
Max retransmit parameters should be set to 1. 
 
 
NOTE – unlimited amount of MCUs can use the same unit ID when in “listener 
only” mode. 
 
 
NOTE – A Mobile MESH network requires at least 2 MCUs configured with 
same Transmission Vector, Frequency and Profile. 
 
9.2  MCU-30 LED indicator 
By  following  the  LED on  the  MCU  the  power  and  link  status  can be monitored,  it  is 
described as follows: 
•  LED is ON – the unit is on, air link is down and no data is transmitted. 
•  LED blinks slowly –1 PPS signal is locked but there is no data over the link 
•  LED blinks fast – Air link is up and data is transferred over the air link 
Link status, CINR, RSSI, Throughput and unit Log are available using the MC-EMA.