G-Way Microwave / G-Wave PS7W3790R Operating Instruction

Page of 18
 
 
4 | 
P a g e
 
 
OVERVIEW 
The BDA assembly enhances the coverage area of radio communications in buildings and RF shielded 
environments. 
The  BDA  has dual RF paths (Down-Link  /  Up-Link) to improve coverage in two distinct frequency 
bands.    
The unit features low noise figure and wide dynamic range. It is based on a dual duplexed path 
configuration with sharp out of band attenuation allowing improved isolation between the receiving and 
transmitting paths. 
BDA-PS7W-37/37-90-R provides up to 37 dBm composite power and has up to 85 db gain. 
 
FCC NOTE 
This is a Class B device. The product has been tested and found to comply with the Booster 
requirements per FCC Part 90.  
 
IC NOTE 
The product has been tested and found to comply with the Industry Canada (IC) RF Exposure 
Requirements, pursuant to IC RSS-131. 
 
NOTE 
The Manufacturer’s rated output power of this equipment is for single carrier operation. For situations 
when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially 
where the output signal is re-radiated and can cause interference to adjacent band users. This power 
reduction is to be by means of input power or gain reduction and not by an attenuator at the output of 
the device. 
 
RF EXPOSURE WARNING-FCC 
The ERP limit, as defined by the FCC is +37 dBm. In order to comply with the FCC RF exposure 
requirements, the antenna installation must comply with the following: 
The Omni directional antenna (or leaky cable) must be installed so as to provide a minimum separation 
distance of at least 30.8 cm (~12.2  inches) between the antenna connected to the RF booster and the 
human user’s body within the area. (This assumes an antenna with gain of 0 dBi, VSWR ≤ 2:1, Zo= 50 
ohms and a cable attenuation less then 1dB). 
Should user choose to utilize a higher gain antenna (greater than 0 dBi) with the system, attenuation of 
the BDA’s gain will be required to meet FCC ERP limit of +37 dBm. 
 
RF EXPOSURE WARNING- INDUSTRY CANADA 
In order to comply with the IC RF exposure requirements, the antenna installation must comply with the 
following: 
For 2 dBi gain antenna: The antenna must be installed so as to provide a minimum separation 
distance of at least 32.5cm (~12.8 inches)  between the antenna connected to the RF booster and the 
human user’s body within the area. (VSWR ≤ 2:1, Zo= 50 ohms and a cable attenuation less then 1dB). 
For 8.5 dBi gain antenna: The antenna must be installed so as to provide a minimum separation 
distance of at least 68.7cm (~27.1 inches)  between the antenna connected to the RF booster and the 
human user’s body 
within the area. (VSWR ≤ 2:1, Zo= 50 ohms and a cable attenuation less then 1dB).