 Processor 5600 Series Datasheet Volume 1
frequencies and voltages. When the TCC is activated, the processor automatically 
transitions to the new operating frequency. This transition occurs very rapidly (on the 
order of 2 µs).
Once the new operating frequency is engaged, the processor will transition to the new 
core operating voltage by issuing a new VID code to the voltage regulator. The voltage 
regulator must support dynamic VID steps to support this method. During the voltage 
change, it will be necessary to transition through multiple VID codes to reach the target 
operating voltage. Each step will be one VID table entry (see 
). The processor 
continues to execute instructions during the voltage transition. Operation at the lower 
voltages reduces the power consumption of the processor.
A small amount of hysteresis has been included to prevent rapid active/inactive 
transitions of the TCC when the processor temperature is near its maximum operating 
temperature. Once the temperature has dropped below the maximum operating 
temperature, and the hysteresis timer has expired, the operating frequency and 
voltage transition back to the normal system operating point via the intermediate 
VID/frequency points. Transition of the VID code will occur first, to insure proper 
operation once the processor reaches its normal operating frequency. Refer to 
 for an illustration of this ordering.
7.2.2.2
Clock Modulation
Clock modulation is performed by alternately turning the clocks off and on at a duty 
cycle specific to the processor (factory configured to 37.5% on and 62.5% off for TM1). 
The period of the duty cycle is configured to 32 microseconds when the TCC is active. 
Cycle times are independent of processor frequency. A small amount of hysteresis has 
been included to prevent rapid active/inactive transitions of the TCC when the 
processor temperature is near its maximum operating temperature. Once the 
temperature has dropped below the maximum operating temperature, and the 
hysteresis timer has expired, the TCC goes inactive and clock modulation ceases. Clock 
Figure 7-12. Frequency and Voltage Ordering
Temperature
f
MAX
f
1
f
2
VIDf
MAX
VID
Frequency
VIDf
2
VIDf
1
PROCHOT#
Time 
Temperature
f
MAX
f
1
f
2
VIDf
MAX
VID
Frequency
VIDf
2
VIDf
1
PROCHOT#
Time