Finisar FTLF8528P2BNV User Manual

Page of 12
FTLF8528P2BNV Pluggable SFP+ Product Specification – November 2007 
 
 
 
© Finisar Corporation November 21, 2007 Rev. B    
Page 2 
I. 
Pin Descriptions  
 
Pin Symbol 
Name/Description 
Ref. 
1 V
EET 
Transmitter Ground  (Common with Receiver Ground) 
2 T
FAULT
 Transmitter 
Fault. 
3 T
DIS
 
Transmitter Disable. Laser output disabled on high or open. 
SDA 
2-wire Serial Interface Data Line (MOD-DEF2) 
SCA 
2-wire Serial Interface Clock (MOD-DEF1) 
MOD_ABS 
Module Absent, connected to V
EET
 or V
EER
  
RS0 
Rx Rate Select: 
Open or Low = 
High = 
 
2.125 or 4.25 Gb/s Fibre Channel (Low Bandwidth) 
8.5 Gb/s Fibre Channel  (High Bandwidth) 
 
LOS 
Loss of Signal indication.  Logic 0 indicates normal operation. 
9 RS1
 
Tx Rate Select: 
Open or Low = 
High = 
 
2.125 or 4.25 Gb/s Fibre Channel (Low Bandwidth) 
8.5 Gb/s Fibre Channel  (High Bandwidth) 
10 V
EER 
Receiver Ground  (Common with Transmitter Ground) 
11 V
EER 
Receiver Ground  (Common with Transmitter Ground) 
12 RD-
 
Receiver Inverted DATA out.  AC Coupled 
 
13 
RD+ 
Receiver Non-inverted DATA out.  AC Coupled 
 
14 V
EER 
Receiver Ground  (Common with Transmitter Ground) 
15 V
CCR
 
Receiver Power Supply 
 
16 V
CCT
 
Transmitter Power Supply 
 
17 V
EET 
Transmitter Ground  (Common with Receiver Ground) 
18 
TD+ 
Transmitter Non-Inverted DATA in.  AC Coupled. 
 
19 TD-
 
Transmitter Inverted DATA in.  AC Coupled. 
 
20 V
EET 
Transmitter Ground  (Common with Receiver Ground) 
 
 
Notes: 
1.  Circuit ground is internally isolated from chassis ground. 
2.  T
FAULT
 is an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on 
the host board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high 
output indicates a transmitter fault caused by either the TX bias current or the TX output power 
exceeding the preset alarm thresholds.  A low output indicates normal operation. In the low state, the 
output is pulled to <0.8V. 
3.  Laser output disabled on T
DIS
 >2.0V or open, enabled on T
DIS
 <0.8V. 
4.  Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and 3.6V. 
MOD_ABS pulls line low to indicate module is plugged in. 
5.  Rate select can also be set through the 2-wire bus in accordance with SFF-8472 v. 10.1
3
.  Rx Rate 
Select is set at Bit 3, Byte 110, Address A2h.  Tx Rate Select is set at Bit 3, Byte 118, Address A2h.  
Note:  writing a “1” selects maximum bandwidth operation.  Rate select is the logic OR of the input 
state of Rate Select Pin and 2-wire bus.   
6.  LOS is open collector output.  Should be pulled up with 4.7k – 10kohms on host board to a voltage 
between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.