Leviton Manufacturing Co. Inc. VRSDC User Manual

Page of 3
Preparing and connecting wires:
This receptacle can be wired using side wire terminal screws or 
through backwire openings. Choose appropriate wire stripping 
specifications accordingly.
WARNING: 
TO AVOID FIRE SHOCK OR DEATH; TURN 
OFF POWER at circuit breaker or fuse and test that power is off 
before wiring!
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble any of 
these configurations, consult a qualified electrician.
WARNINGS AND CAUTIONS
:
•  To be installed and/or used in accordance with electrical codes and regulations.
•  If you are unsure about any part of these instructions, consult an electrician.
•  To ensure that there is adequate room for wires, we recommend using at a minimum 3-1/2 inch deep wallboxes. For single-gang applications, this would be at a 
minimum an 18-cubic inch wallbox.
WARNINGS AND CAUTIONS
:
•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•  Maximum wire length cannot exceed 300 ft (90 m).
•  Use this device with copper or copper clad wire only.
Duplex Receptacle (Top Controlled)
Scene Capable Receptacle
Cat. No. VRR15-1L - 15A - 125VAC, 60Hz
Incandescent-1800W – Magnetic Low-Voltage-1800VA (1440W)
Electronic Low-Voltage-1800W – Fluorescent-1800VA – Supplemental-1/2 HP
INSTALLATION INSTRUCTIONS
DI-000-VRR15-02A
 Tools needed to install your Receptacle
Slotted/Phillips Screwdriver 
Electrical Tape 
Pliers 
 
Pencil 
 
 
Cutters 
 
Ruler
Changing the color of your Receptacle:
Your Receptacle includes three color options. The Receptacle ships with the 
White frame attached. To change color of frame, proceed as follows:
INSTALLING YOUR RECEPTACLE
NOTE: Use check boxes           when Steps are completed.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
 
Step 1
2
4
3
1
Single Pole
1.
  Line (Hot)
2.  Neutral
3.  Ground
 
Step 2
Single Pole Wiring Application:
 
Step 3
•  Make sure that the ends of the wires from the wall box are 
straight (cut if necessary).
•  Remove insulation from each wire in the wall box as shown.
5/8" 
(1.6 cm)
Strip Gage 
(measure bare 
wire here)
Cut 
(if necessary)
Side Wire Connection 
Side wire terminals accept #14-12 
AWG solid copper wire only.
Back Wire (either hole may be used) 
Back wire openings accept #14-12 
AWG solid copper wire only.
WIRING RECEPTACLE:
Connect wires per WIRING DIAGRAM as follows:
•  Green or bare copper wire in wall box to Green terminal screw.
•  Line Hot wall box wire to terminal screw marked "LINE".
•  Line Neutral wall box wire to terminal screw marked "NEUTRAL".
•  Proceed to Step 5.
Leviton’s Vizia RF +™ Z-Wave
®
 components are designed to communicate 
with each other via Radio Frequency (RF) to provide remote control of 
your lighting. Using RF technology allows Leviton to provide the greatest 
signal integrity possible. Each module in Leviton’s Vizia RF +™ component 
line is a Z-Wave
®
 enabled device. In a Z-Wave
®
 network, each device is 
designed to act as a router. These routers will re-transmit the RF signal 
from one device to another until the intended device is reached. This 
ensures that the signal is received by its intended device by routing 
the signal around obstacles and radio dead spots. The Scene Capable 
Electronic Receptacle is compatible with most Z-Wave
®
 enabled networks, 
from different manufacturers and can also be used with other devices 
displaying the Z-Wave
®
 logo.
CAUTION:
Remember to exercise good common sense when using the Timer features 
of your Remote – especially when scheduling unattended devices. There 
can be some unexpected consequences if not used with care. For example, 
an empty coffee pot can be remotely turned on. If that should happen, 
your coffee pot could be damaged from overheating. If an electric heater 
is turned on by remote control while clothing is draped over it, a fire could 
result. DO NOT USE the remote for the control of high power heating 
appliances such as portable heaters.
•  Receptacle ON/OFF 
•  Scene Capable
•  ON/OFF LED
•  Two way communication 
•  RF reliability
•  Ease of installation – No new wiring
•  Compatible with other Z-Wave
®
 enabled devices
 FEATURES
 INTRODUCTION
Testing your Receptacle prior to mounting in 
wall box:
Receptacle Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
•  Restore power at circuit breaker or fuse.
•  Locator light should turn ON.
  If locator light does not turn ON, refer to the TROUBLESHOOTING 
section.
 
Step 5
•  Position all wires to provide room in outlet wall box for device.
•  Partially screw in mounting screws in wall box mounting holes.
  NOTE: Dress wires with a bend as shown in diagram in order to 
relieve stress when mounting device.
 
Step 6
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
 
Step 7
Neutral (Silver)
Line (Black)
Green
Ground
CONTROLLED
Push in side 
at tab to release
Line up tabs and 
press in sides one at a time 
to attach
 
Step 4
CONTROLLED
Installation may now be completed by tightening 
mounting screws into wall box. Attach wallplate.