5.3  Parameters Configuration of the Ethernet Interface 
The first step is to allocate a unique IP address to each L-SP3. This operation will allow 
identifying each L-SP3 on site before configuring them on the Ethernet network. 
 
The L-SP3 configuration will be carried on using a host computer connected to the local Ethernet 
network. 
 
5.4  Configuration of the L-SP3 
“Library Pedestal Configuration Tool” is the software tool used to monitor and configure the 
L-SP3 pedestal.  
 
 
The  whole  L-SP3  configuration  is  carried  on from  a  host computer  connected  to the  local 
area network.  Each L-SP3 is addressed thanks to its own IP. 
5.4.1  Installing the Configuration Software 
The Library Pedestal Configuration Tool is on the CD-Rom provided with the L-SP3. 
Launching the Installer from the CD-ROM will display the following window: 
 
 
Don’t forget to power up your installation before carrying on the 
following steps 
 
By default the IP address is 169.254.0.100 (port 4001) (IPv4 Automatic 
Private IP Addressing). Ask your network administrator to obtain a static 
IP address for each of the pedestals connected to your local network. 
 
You can localize the each gate thanks to their IP address. Their on site 
location must be known to configure and set them as Slaves or Master. 
 
Before you configure the whole L-SP3, you need to have a clear vision of 
which pedestals will be masters or slaves. (Refer to section 5.2 
“Understanding the L-SP3 Synchronization Process”) 
 
In a configuration with several pedestals, as all pedestals are set as 
master by default, they will mutually perturb when powered on. So the 
first step will be to set the appropriate pedestals as slaves.