Tagsys S.A. L200TUNANT500 User Manual

Page of 45
 
CONVEYOR TUNNEL READER User's Guide 
22/45 
Revision 1.0 
November 2007 
 
•  To read the state of an Input from a supervisor, you need to make a read bit at the 
corresponding address. Inputs, by definition, can not be modified. 
•  To read the state of an Output, you need to make a read bit at the corresponding address. 
To modify the state of an Output, you need to make a write bit at the corresponding 
address. 
For more information on the variables addressing on WAGO I/O 750 system, please ask your 
TAGSYS representative or go to 
http://www.wago.com/wagoweb/documentation/index_e.htm
 and 
check manuals concerning 750-842 Ethernet TCP/IP Programmable Controller. 
 
 
4.2.1  Conveyor Commands (for slave mode with external conveyor 
command) 
The conveyor motor is controlled by a Speed Variator Telemecanique Altivar 11.  
 
 
 
Check the position of the small black switch on your PLC. It must be in the position 
corresponding to your case (standalone or slave mode) 
Small Black Switch 
 
Upper position = standalone mode 
Medium position = slave mode 
Do not use lower position.