• To read the state of an Input from a supervisor, you need to make a read bit at the
corresponding address. Inputs, by definition, can not be modified.
• To read the state of an Output, you need to make a read bit at the corresponding address.
To modify the state of an Output, you need to make a write bit at the corresponding
address.
address.
For more information on the variables addressing on WAGO I/O 750 system, please ask your
TAGSYS representative or go to
TAGSYS representative or go to
http://www.wago.com/wagoweb/documentation/index_e.htm
and
check manuals concerning 750-842 Ethernet TCP/IP Programmable Controller.
4.2.1 Conveyor Commands (for slave mode with external conveyor
command)
The conveyor motor is controlled by a Speed Variator Telemecanique Altivar 11.
Check the position of the small black switch on your PLC. It must be in the position
corresponding to your case (standalone or slave mode)
corresponding to your case (standalone or slave mode)
Small Black Switch
Upper position = standalone mode
Medium position = slave mode
Do not use lower position.