Figure 13: Advanced Settings Tab Sections and Fields
Steps to undergo:
1. Prepare a 2 wire cable of appropriate length and number of connectors to wire up each
pedestal. Use the 3.81 mm Green Plugs Vertical Cable Entry with Screw provided.
2. Connect all pedestals Synchronization to the Synchronization I/O as shown on Figure 11.
3. Set each pedestal to hardwire synchronization modifying the “Mode” in the “Synch” Section
of the “Advanced Configuration” tab of the L-SP3 Pedestal Configuration Tool.
4. Write down the MAC address of each pedestal. Use the test button in “Monitoring” tab to
locate it: the connected pedestal will ring and its display lit.
5. Power up the whole system (every pedestal must be powered up) and check that the
synchronization process works properly detecting a book in each passageway.
6. Put the cover panel back into place and secure it with the 4 screws