Tagsys S.A. LSP3STANDARD User Manual
May 2009
Revision 0.2
35/63
5.4.2 Communication Configuration
Figure 14: Communication Configuration Tab (connected to a L-SP3)
This tab is used either:
•
To establish connection to a pedestal when its IP address is known.
•
To discover pedestals connected to the same network as the PC running the configuration
tool.
tool.
•
To modify the TCP/IP configuration of a discovered pedestal (not including port) if this
address is not coherent with the address of the network it is connected to.
address is not coherent with the address of the network it is connected to.
Connecting to a pedestal when its IP address is known
Select “Ethernet/Wifi” as the Com Mode, enters the pedestal IP address and Port in the
appropriate fields and click “Init Communication”. Status bar on top of the window area should now
display pedestal model and firmware revisions.
appropriate fields and click “Init Communication”. Status bar on top of the window area should now
display pedestal model and firmware revisions.
Click “Release Communication” to disconnect from a pedestal.
Discovering pedestals connected to the network