GPIO: Port has no predefined function; it can be driven remotely by Host PC via API. 
• 
Output Trigger: when Theft is detected (EAS or AFI signal setting the alarm), the Port 
Signal level matches the Active Level Setting (“Low” or “High”). The output voltage level of 
the port should match the active voltage to set the external alarm device wired up. 
Whenever the GPIO is set as an Output Trigger, It is possible to set a pulse Width and a Pause in 
ms. In Figure 21, the Pulse Width is set to 100ms. This means that whenever theft detection 
occurs, the signal on port#2 will go from low to high for a minimum time of 100ms. If no further 
detection occurs before the 100ms timing laps, then signal will drop to low level. 
Whenever after the Pause timing, if a new detection occurs, signal will rise again to high level. 
In the particular case of the Pause Timing set to 0ms, whenever detection will occur timing equal to 
Pulse setting will be added up so that the active level will stay high as long as detection will occur 
(so called retrigger configuration). 
Setting pause timing to a value different from zero will force the output signal to low level for Pause 
time after the Pulse time set, before being triggered again by a subsequent detection. 
 
 
Figure 21: GPIO Pulse & Pause Field 
 
 
Figure 22: GPIO Green Connector Pin Out & Location 
Input Output Connector Pin out: 
Port #1 (Open Drain) 
Ground 
Port #2 (Open Drain) 
Ground