10  Performance Test 
10.1  Test Conditions 
  Distance between each pedestal not greater than the maximum recommended distance of 915 
mm (3 ft.).  
  All tags used must have the theft bit set. Use of reference tag (Antenna Tuning Kit Test Card) 
is strongly recommended for repeatable results. 
  Testing to be carried out at walking pace (maximum of 1 meter/second). 
  Metal, conductive materials, human hands or body must not shield tags. 
  All  books  must  have  tags  inserted  according  to  the  4  positions;  20-mm  offset  grid 
recommendation. 
  Minimum thickness of books should be 16 mm 
  Each EAS system shall be installed, commissioned, tuned and operated according to TAGSYS 
instructions. 
10.2  Test Procedure 
1.  Divide  the  gate  into  15  test  zones  as  shown.  Tip:  Use  masking  tape  to  temporarily  mark  the 
floor and pedestals. 
2.  Using  the  locked  reference  tag(s),  walk  through  the  gate  positioning  the  tag  in  the  center  of 
each zone. 
(Start at test zone 1 and sequentially test each zone in turn) 
3.  If either or both pedestals sound an alarm, indicate the zone box with a check mark. If neither 
sounds an alarm, indicate with a cross. 
4.  Repeat the test with the tag in three orientations for each zone. (Vertical, Horizontal & Facing 
positions)  
5.  Mark the random tests with a check mark or cross inside a triangle in the appropriate test zone. 
Figure 32: Tag Orientation 
Horizontal 
Vertical 
Facing 
Random 
 
 
Figure 33: Example 
Additional random test 
Detected 
Detected 
Not detected 
Detected 
 
Zone 13