Tagsys S.A. MEDIOL40 User Manual

Page of 56
 
Medio L40 - User's Guide 
 
 
46/56 
Revision 2.3 
July 2013 
 
 
6.3.4  Using Outputs 
The reader outputs are Open Drain, N-Channel (when activated, an output is tied to the ground). 
They can drive a current up to 1.4A, and accept voltages up to 28V. Outputs are internally pulled-
up  to  3.3V  with  1KOhms  resistors  and  are  protected  against  overload  and  overheat.  Applying 
negative voltage to outputs (polarity inversion) may destroy them. 
 
Figure 25
 below demonstrates how to connect an external load to an output. 
 
Figure 25: Connecting an external load to output #1 
 
 
 
 
External  devices  must  be  connected  to  GPIOs  in  compliance  with 
Table  8
  and  SELV 
requirements.