CommScope Technologies LLC 800002 User Manual

Page of 18
114
Release 2.0, 910011: June 28, 2002
9.
Use a torque wrench with a 5/32 inch tamper-resistant hex drive bit set to 18 inch-pounds to tighten all
screws evenly.
WARNING
If access panels screws are not tightened with the correct torque, electronic interface may occur
causing equipment malfunction.
10. Connect all antenna cables to the proper external antennas/surge protection equipment.
The connections are typically N-type and require a 13/16 inch open ended wrench.
Tighten connections snugly. Do not overtighten.
CAUTION
!
All external antenna cables exiting the Rox System cabinet seal must be connected
to an external surge suppression system, even if the cables are not used. Failure to
connect unused cables to a surge suppression system leaves them open to lightning
strikes, which could damage the IP-RN 8000.
This procedure is complete. Go to
Understanding the module installation process
on page 116.