Gemalto M2M GmbH MC56 User Manual

Page of 104
MC55/56 Hardware Interface Description 
Confidential / Preliminary 
s
 
MC55/56_hd_v03.00 
Page 23 of 104 
16.08.2005 
3.1 Operating 
modes 
The table below briefly summarizes the various operating modes referred to in the following 
chapters.  
Table 3: Overview of operating modes 
Mode 
Function 
GSM / GPRS SLEEP  Various powersave modes set with AT+CFUN 
command.  
Software is active to minimum extent. If the module was 
registered to the GSM network in IDLE mode, it is 
registered and paging with the BTS in SLEEP mode, 
too. Power saving can be chosen at different levels: 
The NON-CYCLIC SLEEP mode (AT+CFUN=0) 
disables the AT interface. The CYCLIC SLEEP modes 
AT+CFUN=5, 6, 7, 8 and 9 alternatively activate and 
deactivate the AT interfaces to allow permanent access 
to all AT commands. 
 
GSM IDLE 
Software is active. Once registered to the GSM 
network, paging with BTS is carried out. The module is 
ready to send and receive. 
 
GSM TALK 
Connection between two subscribers is in progress. 
Power consumption depends on network coverage 
individual settings, such as DTX off/on, FR/EFR/HR, 
hopping sequences, antenna. 
 
GPRS IDLE 
Module is ready for GPRS data transfer, but no data is 
currently sent or received. Power consumption depends 
on network settings and GPRS configuration (e.g. 
multislot settings). 
 
Normal operation 
GPRS DATA 
GPRS data transfer in progress. Power consumption 
depends on network settings (e.g. power control level), 
uplink / downlink data rates and GPRS configuration 
(e.g. used multislot settings). 
 
POWER DOWN 
Normal shutdown after sending the AT^SMSO command.  
The Power Supply ASIC (PSU-ASIC) disconnects the supply voltage from the 
baseband part of the circuit. Only a voltage regulator in the PSU-ASIC is active 
for powering the RTC. Software is not active. The serial interfaces are not 
accessible.  
Operating voltage (connected to BATT+) remains applied. 
 
Alarm mode 
Restricted operation launched by RTC alert function while the module is in 
POWER DOWN mode. Module will not be registered to GSM network. Limited 
number of AT commands is accessible.