Gemalto M2M GmbH MC56 User Manual

Page of 104
MC55/56 Hardware Interface Description 
Confidential / Preliminary 
s
 
MC55/56_hd_v03.00 
Page 48 of 104 
16.08.2005 
3.6.6.1 
Wake-up via /RTS0 and RTS1 (if AT+CFUN=0 or AT+CFUN=9) 
During the CYCLIC SLEEP modes 5, 6, 7, and 8, the /RTS0 and /RTS1 lines are 
conventionally used for flow control: The assertion of /RTS0 or /RTS1 indicates that the 
application is ready to receive data - without waking up the module.  
 
If the module is in CFUN=0 mode the assertion of /RTS0 and /RTS1 serves as a wake-up 
event, giving the application the possibility to intentionally terminate power saving. If the 
module is in CFUN=9 mode, the assertion of /RTS0 or /RTS1 can be used to temporarily 
wake up MC55/56 for the time specified with the AT^SCFG command (default = 2s). In both 
cases, if /RTS0 or /RTS1 is asserted while AT+CFUN=0 or AT+CFUN=9 is set, there may be 
a short delay until the module is able to receive data again. This delay depends on the 
current module activities (e.g. paging cycle) and may be up to 60ms. The ability to receive 
data is signalized by /CTS0 and /CTS1. It is therefore recommended to enable RTS/CTS 
flow control, not only in CYCLIC SLEEP mode, but also in NON-CYCLIC SLEEP mode.