Gemalto M2M GmbH MC56 User Manual

Page of 104
MC55/56 Hardware Interface Description 
Confidential / Preliminary 
s
 
MC55/56_hd_v03.00 
Page 61 of 104 
16.08.2005 
3.12 Control 
signals 
3.12.1 Inputs 
Table 17: Input control signals of the MC55/56 module 
Signal  
Pin 
Pin status 
Function 
Remarks 
Falling edge 
Power up MC55/56 
Ignition 
/IGT 
 
Left open or HiZ  No operation 
Active low 
≥ 100ms (Open 
drain/collector driver to GND 
required in cellular device 
application). 
Note: If a charger and a 
battery is connected to the 
customer application the /IGT 
signal must be 1s minimum. 
 
Low 
Power down 
MC55/56 
Emergency 
shutdown 
/EMERG-
OFF 
Left open or HiZ  No operation 
Active low 
≥ 3.2s (Open 
drain/collector driver required 
in cellular device application). 
At the /EMERGOFF signal the 
watchdog signal of the GSM 
engine can be traced (see 
description in Table 26). 
 
 
(HiZ = high impedance)