Gemalto M2M GmbH MC56 User Manual
MC55/56 Hardware Interface Description
Confidential / Preliminary
Confidential / Preliminary
s
MC55/56_hd_v03.00
Page 69 of 104
16.08.2005
4.1.2
Hirose antenna connector
MC55/56 uses an ultra-miniature SMT antenna connector
supplied from Hirose Ltd. The product name is:
supplied from Hirose Ltd. The product name is:
U.FL-R-SMT
Figure 30: Mechanical dimensions of U.FL-R-SMT connector
Table 21: Product specifications of U.FL-R-SMT connector
Item
Specification
Conditions
Ratings
Nominal impedance
50
Ω
Rated frequency
DC to 6 GHz
Operating temp: -40°C to +90°C
Operating humidity: max. 90%
Operating humidity: max. 90%
Mechanical characteristics
Female contact holding
force
force
0.15 N min
Measured with a
∅ 0.475 pin
gauge
Repetitive operation
Contact resistance:
Centre 25 m
Centre 25 m
Ω
Outside 15m
Ω
30 cycles of insertion and
disengagement
disengagement
Vibration
No momentary disconnections of
1 µs;
No damage, cracks and looseness
of parts
1 µs;
No damage, cracks and looseness
of parts
Frequency of 10 to 100 Hz,
single amplitude of 1.5 mm,
acceleration of 59 m/s
single amplitude of 1.5 mm,
acceleration of 59 m/s
2
, for 5
cycles in the direction of each of
the 3 axes
the 3 axes
Shock
No momentary disconnections of
1 µs.
No damage, cracks and looseness
of parts.
1 µs.
No damage, cracks and looseness
of parts.
Acceleration of 735 m/s
2
, 11 ms
duration for 6 cycles in the
direction of each of the 3 axes
direction of each of the 3 axes
Environmental characteristics
Humidity resistance
No damage, cracks and looseness
of parts.
Insulation resistance:
100 M
of parts.
Insulation resistance:
100 M
Ω min. at high humidity
500 M
Ω min when dry
Exposure to 40°C, humidity of
95% for a total of 96 hours
95% for a total of 96 hours
Temperature cycle
No damage, cracks and looseness
of parts.
Contact resistance:
Centre 25 m
of parts.
Contact resistance:
Centre 25 m
Ω
Outside 15m
Ω
Temperature: +40°C
→ 5 to 35°C
→ +90°C → 5 to 35°C
Time: 30 min.
Time: 30 min.
→ within 5 min. →
30 min.
→ within 5 min
Salt spray test
No excessive corrosion
48 hours continuous exposure to
5% salt water
5% salt water