Gemalto M2M GmbH MC56 User Manual

Page of 104
MC55/56 Hardware Interface Description 
Confidential / Preliminary 
s
 
MC55/56_hd_v03.00 
Page 98 of 104 
16.08.2005 
7 Reference 
Approval 
7.1 
Reference Equipment for Type Approval 
The Siemens reference setup submitted to type approve MC55/56 consists of the following 
components: 
•  Siemens MC55/56 cellular engine 
•  Development Support Box (DSB45) 
•  Flex cable (160 mm) from Hirose DF12C receptacle on MC55/56 to Hirose DF12 
connector on DSB45. Please note that this cable is not included in the scope of delivery 
of DSB45. 
•  SIM card reader integrated on DSB45 
•  Handset type Votronic HH-SI-30.3/V1.1/0 
•  PC as MMI 
 
 
 
GSM engine
 
PC
 
Power supply
 
SIM
Flex cable
160mm 
RS-232
 
DAI Box
 
DSB45
Handset
Acoustic tester
 
Antenna or 50 
Ω
 
cable to system 
simulator
 
Antenna
DAI cable for 
acoustic measuring
 
 
Figure 44: Reference equipment for approval