Falcom GmbH FOX User Manual

Page of 31
FOX H
ARDWARE
 M
ANUAL
                      - P
RELIMINARY
 -
V
ERSION
 1.0.0
5 FOX APPLICATION INTERFACE
5.1 Power supply
The power supply for the FOX unit has to be a single voltage source of V
+IN 
= +10.8 
V...+35.0 VDC. The operating voltage (V
+IN
) has to be permanently applied to the 
FOX unit and able to provide sufficient current of up to 1.9 A. 
The operating voltage (V
+IN 
and GND) is protected 
against voltage spikes and reverse 
polarity, but not 
against overvoltage.
NOTE:  Operating voltage range must never be exceeded; care must be taken in 
order to fulfill min/max voltage requirements.
5.1.1 Power supply pins (1 and 2) on the 8-pin connector
 
 
One +IN pin on the 8-pin connector is dedicated to connect the supply voltage, 
and the GND pin for grounding.
Both +IN and GND pins serve for charging the internal Li-Polymer battery (option) 
and powering the FOX device. FOX has
 an automatic power ON-function when 
external power is applied. The power supply for the FOX is capable of utilizing 
current   ranging   from  V
+IN  
=   +10.8   V   ...   +35.0   VDC   designed   for   automotive 
application. 
Signal name 
I/O 
Parameter
Description
+IN
I
+10.8   V...+35.0   VDC.   The 
operating   voltage   must   never 
be exceeded.
Positive operating voltage. 
For   security   reason,  it   is   recommended   to   integrate 
externally a 2A fuse link between interconnection plug (8-
pin connector) and d.c.-power source (see Fig 14).
GND
-
0 V
Ground (should be isolated from the vehicle Grounds)
5.1.2 Automatic shutdown
 
 
Automatic shutdown takes effect if:
under voltage is detected when battery level runs low and external power 
supply is disconnected .
The automatic shutdown procedure is equivalent to the initiated power-down, 
i.e.   FOX   logs   off   from   the   network   and   the   software   enters   a   secure   state 
avoiding loss of data.
5.2 Determining the External Equipment Type
Before you connect the serial port pins on the aforementioned terminals (DCE units) 
to external equipment, you need to determine if the external hardware serial ports 
are configured as DTE or DCE.
FOX   is   designed   for   use   as   a   DCE   device.   Based   on   the  aforementioned 
conventions   for   DCE-DTE   connections,   it   communicates   with   the   customer 
application (DTE) using the following signals:
FOX Terminal (DCE)
to
Application (DTE)
RxA
<----------
TXD
TxA
---------->
RXD
Table 4:
The signalling definitions between DTE and DCE.
This confidential document is a property of FALCOM and may not be copied or circulated without previous permission.