6.1.2 Special pin description (Pins 4, 5, 6)
 
 
All these pins are controlled by the internal firmware. All of them can be configured 
for used either as analog or digital input or digital output.  Some examples how to 
use them are given in sections below
.
For IO lines that can work as input or output the corresponding output of this pin 
has to be set to high (with PFAL command “
$PFAL,IO4
[5,6]
.Set=high”
), otherwise 0V 
will be measured
 (and the device could be damaged).
6.1.2.1
How to use these pins as analog inputs
Because these pins can operate either as digital or analog inputs, they have to be  
configured and calibrated   with the help of PFAL commands supported by the 
firmware before using as analog inputs.
Analog voltages of up to 35.0 V with a 10 bits resolution can be processed and 
remotely  evaluated   by   a  server  application.  Pull-up  resistor  to  a  constant  input 
voltage allows for resistive transducers to ground, e.g. fuel sensor or thermistors. 
To use these IOs as analog inputs, the following configuration is required in the 
software.
PFAL,IO
0[1,2]
.Config=AI,2,11 
where 0, 1 and 2 are indices corresponding to IO1 (pin 4), IO2 (pin 5) and IO3 (pin 6) 
respectively. While the value 2 and 11 are min. and max. voltages that will be used to  
generate   Low   and   High   events,   respectively.  
Detailed   information   can   be   found   in 
software manual “steppIII_fox_bolero_lt_PFAL_Configuration_Command_Set.pdf
 Connection example 1 (for I/O1 and I/O2):
Thus, an analog input can be connected to a temperature sensor (a NTC 
resistor for instance). In the diagram below, it is used a fixed resistor from the  
input voltage to the I/O 2, and a variable resistor (
Negative Temperature Coefficient 
- whose resistance or capacitance decreases when temperature increases
) to ground. It is 
possible  to  set   a  low  temperature  alarm  and  a   high   temperature  alarm 
(upper and lower values), passed to required temperature. Passage through 
these thresholds will trigger an alarm. We recommend to use SMS or TCP as 
alarm type with GPIOP as attachment protocol. The SMS can be received  
on a mobile phone, modem or any GSM device when changes are notified. 
The  analog-to-digital converter (ADC)  inside the unit has an input voltage 
range from 0 to 2.5 V.  An application example is shown in figure below:
Figure 4:
Connection example 1 when using it as analog input. 