Wireless Passive Infrared Detector DCMT-2500 User Manual 
 
 
The DCMT-2500 is a wireless PIR sensor that is compatible with DCR-2500 receivers.  It is 
designed for indoor and outdoor use.    When the sensor detects an object it will send a signal to 
the receiver which will sound one of four different tones (Classical, Westminster Chime, Ding 
Dong, Whistle) for a few seconds. 
 
Operation: 
 
1.  Connect a 9-volt alkaline battery. 
2.  Set the dip switches 1-8 to match the receiver. 
3.  Set dip switches 9 and 10 to control the desired zone, tune, and relay output. 
4.  Mount on wall 6 to 8 feet high slightly pointing down. 
 
Detection Range:  High – 25 meters 
    Medium 
– 
15 
meters 
 
 
 
 
Low – 7 meters 
LED: 
 
 
ON- led will flash when it detects 
    OFF- 
led 
is 
always 
black 
Filter: 
 
 
ON – set for outdoor use 
    OFF 
– 
set 
for 
indoor 
use 
Reset: 
 
 
10 seconds for reset after activation 
                                120 seconds for reset after activation 
 
Low Battery Alert: If the receiver sounds a second alert 30 seconds after the first alert, provided 
nothing trips the sensor again, the 9 – volt battery on the DCMT2500 detector should be changed.     
 
Frequency: 433.92MHz 
Operating range: -20°C to 60°C 
Battery Life:    6 – 12 months 
 
Warning:  
 
Changes or modifications to this unit not expressly approved by the party responsible for 
compliance will void the user’s authority to operate the equipment. Any change to the equipment 
will void FCC grant. 
This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off