Sagem Wireless MA110 User Manual

Page of 50
 
L
L
E
E
D
D
 
 
I
I
N
N
 
 
A
A
C
C
T
T
I
I
V
V
A
A
T
T
I
I
O
O
N
N
 
 
Use this signal to wait a controller “ACK” before granting the access. 
 
 
 
 
 
 
User ID 
 
LED1 to GND: Access authorized. 
LED2 to GND: Access refused. 
 
 
1- If the user is recognized the MA1XX sends the user identifier to the 
controller. 
2 - The MA1XX waits for a GND signal on LED1 or LED2. A timeout can 
be defined. 
3 - The controller checks the user rights. 
4 - The controller sets LED1 to GND to authorize the access or sets LED2 
to GND to forbid the access. 
5 – The control restarts only when LED1 and LED2 are set to “1” again. 
This feature improves integration in an access control system (ACS). The 
ACS through LED IN signals validates result of biometric matching. 
LED IN mode activation 
app/led IN/enabled 
1
When the ACS validates the control a timeout must be specified: it defines 
the time during which the MorphoAccess™ will wait for an 
acknowledgement signal from the ACS through LED IN signals 
LED IN “acknowledgement timeout” in 10 ms 
app/led IN/controller ack timeout 
0 to 268435455
 During the time LED1 or LED2 is set to GND the control DOES NOT 
RESTART. 
34 
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden