Product Technical Specification 
Reliability Specification (TBC) 
6.2.2. 
Environmental Resistance Stress Tests 
The following tests the AirPrime HL77xx modules’ resistance to extreme temperature. 
Table 40. 
Environmental Resistance Stress Tests 
Designation 
Condition 
Cold Test Active 
COTA 
 
Standard: IEC 680068-2-1, Test Ad 
Special conditions: 
 
Temperature: -40°C 
 
Temperature variation: 1°C/min 
Operating conditions: Powered ON with a power cycle of 1 minute ON and 
2 minutes OFF 
Duration: 3 days 
Resistance to Heat Test 
RH 
 
 
Standard: IEC 680068-2-2, Test Bb 
Special conditions: 
 
Temperature: +85°C 
 
Temperature variation: 1°C/min  
Operating conditions: Powered ON with a power cycle of 15 minutes ON 
and 15 minutes OFF 
Duration: 50 days 
6.2.3. 
Corrosive Resistance Stress Tests 
The following tests the AirPrime HL77xx modules’ resistance to corrosive atmosphere. 
Table 41. 
Corrosive Resistance Stress Tests 
Designation 
Condition 
Humidity Test 
HUT 
 
 
Standard: IEC 60068-2-3, Test Ca 
Special conditions: 
 
Temperature: +65°C 
 
RH: 95% 
 
Temperature variation: 3 +/- 0.6°C/min  
Operating conditions: Powered on, DUT is powered up for 15 minutes and 
OFF for 15 minutes 