Ewig Industries Macao Commercial Offshore Limited 882F01 User Manual

Page of 3
3. BATTERY INSTALLATION – Very Important
Note: The batteries must be installed  in the following sequence in order to activate  the outdoor temperature sensor.
1
st
. Insert the batteries into  the indoor receiving unit.
2
nd
. Insert the batteries into the outdoor remote sensor.
NOTE: When replacing the batteries, in the receiving unit, please repeat all steps in point 3.  When replacing the batteries, in  any of
the remote sensor units (if more than 1), please refer to point 13. It is important to note that new batteries are always to be
used. Do not mix old and new batteries as the old ones may leak. Furthermore, in order to protect our environment, please
dispose the old batteries promptly and properly. Please do not burn or bury them.
Set Up instructions for:
For the receiving unit
a. Press the cover tab, and slide down the battery compartment cover at the back of the receiving unit.
b. Insert 2 AAA size batteries according to the polarity marks “+” and “-” shown in the battery compartment.
c.
The (OUT) icon and the dash (---) icon will flash at the bottom of the LCD display. The receiving unit is now ready to receive a signal from the RF remote
sensor  unit.
For the remote sensor unit
a. Remove the removable stand and wall-mount of the remote sensor unit by releasing the 2 fixing snaps at the bottom of the unit and pulling it so as to
lift it off the sensor.
b. Using a small Philips screwdriver, unscrew the 4 screws that allow the battery compartment cover to stay in place.
c.
Once the 4 screws are completely loosened, remove the cover.
d. Insert 2 AAA size batteries according to the polarity marks shown in the battery compartment.
e. Once the batteries are  inserted in the battery compartment, the sensor will  automatically transmit a temperature signal to the  receiving unit at 30-
second intervals. The sensor is also  equipped with a manual transmission button (TX/HOLD RESET). If auto-registration  is not successful, press this
button for 2 seconds, the remote sensor will automatically send a temperature signal to the receiving unit.
f.
The temperature read by the remote sensor will appear at the bottom of the LCD display. If it does not, repeat all steps of point 3. BATTERY
INSTALLATION.
g. Once registration of the signal is confirmed, the icon “1” will appear in the upper left corner of the bottom part of the LCD. Reinstall the rubber seal
into the cover groove, and close the battery cover. Tighten  the screws, and snap on the removable stand and wall-mount.
Note: After placing the remote sensor in its desired location, it may take up to 5 minutes for the receiving unit to display the
temperature read by that particular remote. If the (---) dash icon appears and flashes, this indicates that the signal has
been interrupted. In this case, rotate the sensor in steps of 45°, and wait at least 3 minutes at each step. If the (---) dash  icon
stops flashing, press and hold the [SNOOZE/LIGHT] button for 5 seconds so as to allow the receiving unit to re-register the
temperature read by the remote. The (---) dash icon will flash again. If the receiving unit is still not registering after this  proce
dure, please move the remote closer to the receiving units or reposition both units until the receiving unit registers the remote
sensor’s readings. For better results, the transmission range should not exceed 100 feet (30meters) in a relatively open space
area. Do not confine either unit in a steel container or heavily insulated room.
4. ADDING  ADDITIONAL  REMOTE  TEMPERATURE  SENSORS  (OPTIONAL)
The 883F01 is designed to receive signals from a maximum 3 different remote temperature sensors. Following are some brief instr uctions for the basic setup
of remote temperature  sensor units with the 883F01. These extra sensors can be  purchased by contacting Springfield Instruments  Company of Canada
directly at (514) 748-6721.
Note:  When setting up multiple units it is important to remove the batteries from all existing units in operation, then to insert
batteries first into the receiving unit, and second into all the remote temperature sensor units  in numeric sequence.
Transmission problems will arise if this is not done correctly and if the total time for set-up exceeds 6 minutes.
1. It is necessary to remove the batteries from all units currently in operation.
2. Remove the battery covers of the receiving  unit and all remote temperature sensor units.
3. Place all  remote temperature sensor units  in a numeric  sequential order.
4. Insert batteries in the receiving unit as described in point 3.
5. In sequential order, install batteries in the remote sensor uni ts as described in point 3. Please do not insert batteries in all remote sensors at the same
time, otherwise this will cause unsuccessful registration. So, you must wait for the registration of the first remote to be completed (i.e. the temperature
read by the first remote will be displayed at the bottom of the LCD and the icon “1” will appear indicating that the first remote has registered). Then
insert the batteries in the second remote sensor, and wait for the registration to be completed (i.e. the temperature read by the second remote will be
displayed at the bottom of the LCD and the icon “2” will appear indicating that the second remote has registered). If you have a third remote, only after
the second remote has registered can you install the batteries in the third one, and wait for registering. If either one of the remotes fails to register,
please repeat all steps of point 4.
Note:
After placing the remote sensors in their desired location, it may take up to 5 minutes for the receiving unit to display  the
temperature read by a particular remote. If the (---) dash icon appears and flashes for a particular remote, this indicates
that the signal has been interrupted. In this case, rotate the sensor in steps of 45°, and wait at least 3 minutes at each step .
If the (---) dash icon stops flashing, press and hold the [SNOOZE/LIGHT] button for 5 seconds so as to allow the receiving
unit to re-register the temperature read by the remote. The (---) dash icon will flash again. If the receiving unit is still not
registering after this procedure, please move the remote closer to the receiving or reposition both units until the receiving
unit registers the remote sensor’s readings. For better results, the transmission range should not exceed 100 feet (30meters)
in a relatively open space area. Do not confine either unit in a steel container or heavily insulated room.
5. VIEWING AND OPERATING  WITH MULTIPLE REMOTE  TEMPERATURE SENSOR UNITS
1. To view the temperature of a different remote temperature sensor unit, press [CHANNEL] button.  A shift from one “boxed” number to the next should
be observed in the bottom part of the LCD. The receiving unit also has an auto scroll feature allowing it to automatically shift from one remote sensor to
the  next.
2. To enable the auto scroll function, press and hold the [CHANNEL] button for 3 seconds. An icon “
” will be displayed at the bottom part of the LCD. Too
disable the auto scroll, press and hold the [CHANNEL] button for 3 seconds.
6. MAX/MIN  TEMPERATURE
a. The receiving  unit records  the maximum  and minimum  indoor and  outdoor temperature  readings.
b. To view the Maximum/Minimum  temperature: first select from which remote temperature  sensor you wish to read the  information (indicated by the
“boxed”  number).
c.
Press the [MAX/MIN] button  once to read the maximum  temperature recorded.
d. Press the [MAX/MIN] button a second time to  read the minimum temperature recorded.
INDOOR THERMOMETER WITH OUTDOOR WIRELESS TEMPERATURE SENSOR
with clock and snooze alarm
MODEL: 883F01
INSTRUCTION  MANUAL
1. INTRODUCTION
Thank you  for purchasing our Indoor/Outdoor  thermometer with wireless  thermometer sensor. The  receiving unit is designed  to register temperature  from a
wireless remote sensor, which sends the temperature of its location to the receiving unit via a 433 MHz signal. It is also poss ible to order additional remote
sensors, but only a maximum of 3 remotes can be operated for one receiving unit. It is also equipped with a snooze alarm and a  time display. To ensure
proper operations, please read this instruction manual carefully and save  it for future reference.
2. DESCRIPTION  OF  BUTTONS
A. [SNOOZE/LIGHT]  button
Press to activate the snooze function when the alarm signal sounds, or to turn on the backlight for 5 seconds.
B. [MODE]  button
Press to toggle between the alarm time and the actual time display.
When the actual time is displayed, press and hold to enter the clock setting mode.
C. [ALERT]  button
Press to enable  or disable the temperature  alert function.
When in alert mode, press and hold to enter the temperature alert setting mode.
D. [CLR]  button
Press to clear the recorded  maximum and  minimum indoor and outdoor temperatures.
E. [MAX/MIN]  button
Press to  display the maximum and  minimum indoor and  outdoor temperatures.
F.
[-]  button
Press in clock setting mode to select the desired minutes, or press during temperature alert setting mode to decrease the temperature to the desired
boundary.
G. [+(°C/°F)]  button
Press to select the temperature display in Celcius (°C) or Fahrenheit (°F), or press during temperature alert setting mode to increase the temperature to
the  desired  boundary.
H. [CHANNEL]  button
Press to display the temperature recorded by the different remote sensors (if more than one remote sensor was installed), or to select the auto scroll
mode (
) so that the receiving unit scrolls automatically from one channel to the other..
I.
[RESET] button  (located  inside  the  battery  compartment)
Press and hold to return all settings back to their original values (set at the factory).
Lift off this part
RF  R EMOT E SEN SOR
TX / HO LD RE SET
CHANNEL
H
A
D
B
F
I
RESET
Hold Seek
E
C
G