This manual is under review by SmarTire – DO NOT ISSUE 
Transmitters – Strap Mount  
 
Battery Life (Projected) 
8.5 Years (normal vehicle use) 
Operating temperature range 
-40° F to 185° F  (-40° C to 85° C) 
Storage temperature Range 
-40° F to 185° F  (-40° C to 85° C) 
Operating humidity 
100% 
Data transmitted 
Pressure, temperature, battery voltage 
Data transmission rate 
Every 4 to 6 minutes (more frequently during a pressure loss 
incident) 
Weight 
To be determined 
Size 
To be determined 
Frequency 
433.92 Mhz 
Pressure Range 
90 PSI absolute (75 PSI gauge) 
Pressure accuracy 
+/- 2  PSI 
Temperature accuracy 
+/- 3 ºC 
Start-stop mode 
Vehicle motion greater than 10kph 
Method of mounting 
Strap around the drop center of wheel 
 
Transmitters – Valve Mount 
 
Battery Life (Projected) 
8.5 Years (normal vehicle use) 
Operating temperature range 
-40° F to 185° F  (-40° C to 85° C) 
Storage temperature Range 
-40° F to 185° F  (-40° C to 85° C) 
Operating humidity 
100% 
Data transmitted 
Pressure, temperature, battery voltage 
Data transmission rate 
Every 4 to 6 minutes (more frequently during a pressure loss 
incident) 
Pressure Range 
90 PSI absolute (75 PSI gauge) 
Weight 
23 gm. (without valve which is 20 gm.) 
Size 
To be determined 
Frequency 
433.92 Mhz 
Pressure accuracy 
+/- 2  PSI 
Temperature accuracy 
+/- 3 ºC 
Start-stop mode 
Vehicle motion greater than 10kph 
Method of mounting 
Mounted on valve