4.2 Over Voltage Protection 
The power supply shall shut down in a latch off mode when the output voltage exceeds the over voltage 
limit shown in Table 4. 
Voltage 
 Minimum 
Maximum 
 Shutdown 
Mode 
+5V +5.7V 
+6.5V 
Latch 
Off 
+3.3V +3.9V 
+4.5V 
Latch 
Off 
+12V +13.3V 
+14.5V 
Latch 
Off 
5VSB 5.7V 
6.5V 
Auto 
recovery 
Table 15 –Over Voltage protection 
 
4.3 Short Circuit Protection 
The power supply shall shut down in a latch off mode when the output voltage is short circuit. 
 
 
5. Environmental Requirements 
5.1 Temperature 
Operating Temperature Range: 
0
°C ~ 50°C (32°F~ 122°F) 
Non-Operating Temperature Range: -40°C ~ 70°C (-40°F~ 158°F) 
 
5.2 Humidity 
Operating Humidity Range: 
20% ~ 90%RH non-condensing 
Non-Operating Humidity Range: 
5% ~ 95%RH non-condensing 
 
6. Agency Requirements 
6.1 Safety Certification. 
Product Safety:   
UL 60950-1 2000Edition, IEC60950-1, 3
rd
 Edition
EU Low Voltage Directive (73/23/EEC) (CB) 
TUV, CCC 
RFI Emission: 
FCC Part15 ( Radiated & Conducted Emissions )
CISPR 22,3
rd
 Edition / 
EN55022: 1998 + A1: 2000
PFC Harmonic: 
EN61000-3-2:2000
 
Flicker: 
EN61000-3-3: 1995 + A1: 2002
 
Immunity against: 
EN55024: 1998 + A1: 2001 and A2: 2003