Inovonics Wireless Corporation 3B6ETOEMM User Manual

Page of 3
Introduction
2
Inovonics Wireless Confidential: Subject to Non-Disclosure Agreement
Secondary alarm  
Connects a secondary end-device to provide RF alarm data for any 
user-specific application.
Tamper input  
Connects a tamper input to send a message when user-specific end-device 
is tampered with.
Reset input  
Connects a reset input, to reset the RF module after a frequency band 
selection change or N/O - N/C selection change.
Power  
The E*1941 has an on-board voltage regulator. Connect power cabling to an 
external power supply of 2.5 to 5.5 volts. Voltage must be sustained at 2.5 volts or above 
and supply 50 milliamps during the transmit cycle.
Ground  
Connects a ground.
Primary alarm  
Connects a primary end-device to provide RF alarm data for any user-
specific application.
Mounting Hole  
Used to mount the RF module to the user-specific product. The 
mounting hole should only be used with a nylon standoff, never metal.
Connection
Output Jumper N/O
Output Jumper N/C
Primary Alarm
Open
Alarm Clear
Alarm
Ground
Alarm
Alarm Clear
Secondary Alarm
Open
Alarm Clear
Alarm
Ground
Alarm
Alarm Clear
Tamper
Open
Alarm
Alarm
Ground
Alarm Clear
Alarm Clear
Reset
Open for normal operation; connect to the ground and release for a board 
reset.