Inovonics Wireless Corporation 3B6ETVCSM User Manual
arrows to scroll through the faults. Resolve the issue with the action
listed in Description of Fault Codes chart.
listed in Description of Fault Codes chart.
TO REMOVE A TAMPER FAULT
1. Select CLEAR.
2. Use the keypad to enter the master code.
3. Select OK.
2. Use the keypad to enter the master code.
3. Select OK.
Full One Year Warranty
The D
E
WALT JobSite Security Portable Alarm System is warranted for
one year from date of purchase. We will repair, without charge, any
defects due to faulty materials or workmanship. For warranty repair
information, visit www.dewalt.com or call 1-800-4-D
defects due to faulty materials or workmanship. For warranty repair
information, visit www.dewalt.com or call 1-800-4-D
E
WALT
(1-800-433-9258). This warranty does not apply to accessories or
damage caused where repairs have been made or attempted by
others. This warranty gives you specific legal rights and you may have
other rights which vary in certain states or provinces.
damage caused where repairs have been made or attempted by
others. This warranty gives you specific legal rights and you may have
other rights which vary in certain states or provinces.
Fault Code Fault Display
Description
Action
DevPower
Primary Power No battery power
Change battery,
Lost Device #
in device
reset
DevLowBatt
Low Battery
Device battery
Change battery,
Device #
low
reset
WeakSig
Weak Signal Transmission signal Check for interference;
Device #
from device is weak
move device
Unsecured
Unsecured
Device has
Check for intrusion;
Device #
been tripped
re-secure device
NoCheckIn
No Check In
Device check-in
Check for interference;
Device #
messages have
move device
not been received
Tamper
Tamper
Device has been
Close device or
opened or damaged
replace if damaged
DESCRIPTION OF FAULT CODES