a. If using the wall tamper function for increased security, mount 
the housing back plate per Figure 3, ensuring the tamper switch 
is depressed.
 Figure 3  EN1240-60 mounting back plate
b. If not using the wall tamper, mount the housing back plate 
using all appropriate hardware.
3 Mounting Considerations
The following should be considered when mounting the EN1240-60:
• The activity sensor should be mounted such that the expected 
intrusion motion is perpendicular to the protection zones
• The activity sensor may not detect motion behind obstructions, 
including blinds, curtains, and drapes
• The activity sensor should be mounted on a solid, vibration-free 
mounting surface
• Fans and blowers can cause false alarms.
• The following may cause false alarms:
-  Fans
-  Blowers
-  Drafts
-  Windows
-  Heat and cooling sources
-  Sunlight
-  Animals
4 Optional Ceiling/Wall Mount Application
The optional ceiling and wall mount brackets are available separately from 
Inovonics, part number ACC665.
Note: Applications that require the back tamper cannot use the ceiling or 
wall mount bracket.
 Figure 4  Ceiling and wall mount brackets
To mount a ceiling or wall bracket:
1. Remove the pcb board.
2. Attach the housing to the bracket.
 Figure 5  Remove the pcb board and attach the housing to the bracket
3. Replace the pcb board.
5 Test the EN1240-60
Caution: The EN1240-60 should be tested after registration, and at least 
once a year thereafter, to ensure operation. To test the EN1240-60, activate 
each of the conditions and ensure an appropriate response.
5.1 Perform a Walk Test
The walk test is performed to ensure motion is sensed and an RF 
transmission results. To perform a walk test:
1. Swipe a magnet past the reed switch. The five minute walk test will 
begin; every time motion is sensed, the LED will light.
Note: During walk test, the EN1240-60 will not transmit alarms when 
motion is detected; only the LED will light.
2. Walk in front of the activity sensor to test the sensor. 
3. After five minutes the walk test will automatically end.
6 Operation
The EN1240-60 transmitter signals an alarm condition when motion is 
detected by the sensor. 
 Figure 6  Standard mounting height and range
7 US Patent Numbers
• 7,154,866
• 7,554,932
• 7,746,804
• Other patents pending
Mount either 
corner or wall 
with screw only
Mount either 
corner or wall with 
screw and wall 
anchor
Mount either corner 
or wall with screw 
only
Ceiling mount
Wall mount
6’ 10”- 
8’ 10”
49’