Inovonics Wireless Corporation 3B6OT9EPT User Manual

Page of 2
3.15.18 07230A © Inovonics, 2018 - www.inovonics.com
EN1550EP Encoder Pulse Transmitter
Installation and Operation Manual
1 Overview
Connected to a Neptune E-CODER® register for submetering, the 
EN1550EP encoder pulse meter transmitter will transmit data to an RF 
receiver that is connected to an Inovonics receiver and data logger.
1.1 Inovonics Wireless Contact Information
If you have any problems with this procedure, contact Inovonics Wireless 
technical services:
• E-mail: support@inovonics.com
• Phone: (800) 782-2709; (303) 939-9336
1.2 EN1550EP Components
 Figure 1  EN1501/EN1501-XL Components
1.3 What’s In The Carton
• Three drywall anchors.
• Three mounting screws.
• One piece of mounting tape.
2 Installation and Startup
2.1 Installation Notes
• These products are designed to be maintained by professional 
submetering technicians.
• Products are tested for indoor use.
• All products should be manually tested weekly.
2.2 Connect Transmitter to Neptune E-CODER Register
Connect the transmitter to the register as follows:
1. Open the housing by pressing down on the base tab near the wiring 
through-hole while lifting away the cover. 
2. Fully insert stripped wires into the removable header terminal.
3. Use a small Phillips screwdriver to tighten the screws that secure wires 
to the removable header terminal.
4. Attach removable header terminal (if removed) to the transmitter board 
as shown.
 Figure 2  Connect the transmitter to the Neptune E-CODER register
2.3 Mount the Transmitter
5. Use the double-sided tape to mount the transmitter to a clean wall.
6. As desired, secure the transmitter to the wall with the mounting bracket, 
screws, anchors and/or mounting tape. 
Note: To secure the EN1550EP, you will need to remove the battery to 
access the mounting screw hole. Make sure to press the reset button after 
replacing the battery to initialize the transmitter.
Note: Ensure cabling enters the housing through the access wiring 
through-hole, and replace the housing (Figure 2).
 Figure 3  Mount the Transmitter
2.4 Register the Transmitter
7. Confirm that transmitter is connected to the meter.
8. Confirm that the battery is installed.
9. Press reset to take the transmitter out of shipping/sleep model.
10. See the appropriate user documentation for specific registration 
instructions.
3 Replace the Battery
When the low battery message is received, you will need to replace the 
EN1550EP battery.
1. Open the housing by pressing down on the base tab near the wiring 
through-hole while lifting away the cover.
2. Remove the old battery, taking note of the battery orientation.
3. Insert the new battery, making sure it is aligned correctly.
4. Press the reset button.
Note: EN1550EP transmitters retain programming data in non-volatile 
memory. They do not require reprogramming after loss of power. Install 
new battery and press the transmitter reset button to initialize the 
transmitter and restore programming. Its count will go to zero and the initial 
Meter Read count will be updated in the data logger.
Battery
Tamper switch
Removable header 
terminal
Reset button
A
B
C
D
Anchor installed in wall
Double-sided tape
Mounting screw
Black wire to terminal B on register
Green wire to terminal G on register
Red wire to terminal R on register
A
B
C