Inovonics Wireless Corporation 3B6OT9GSKC User Manual

Page of 4
10.16.17 06884D © Inovonics, 2017 - www.inovonics.com
EN1245 Family Wireless CO Detector
Installation Instructions
1 Overview
The wireless CO detector features an onboard sounder, a CO sensor, LED 
indicators and local test capability to allow the user total visibility of its 
functionality. It is self-monitoring, alerting the user when sensor 
maintenance is needed or batteries are low and automatically supervising 
the radio link.
The wireless CO detector is available in the following configurations:
The wireless CO detector is intended for open area protection and for 
connection to a compatible control unit for operation as part of a household 
fire alarm system (UL985).
Note: For  UL 2560 installations, refer to the EN6080 Area Control 
Gateway Installation Instructions
.
1.1 Maximum Number of Repeaters for a UL 2560 
Installation
To achieve the 99.99% alarm message reliability required for UL 2560 
compliance, system installations must operate within the following limits for 
end device and repeater counts.
1.2 
Inovonics Contact Information
If you have any problems with this procedure, contact Inovonics technical 
services:
• E-mail: support@inovonics.com.
• Phone: (800) 782-2709; (303) 939-9336.
1.3 Wireless CO Detector External Components
 Figure 1  Wireless CO detector external components
Device Indicators
1.4 What’s In The Carton
• One 3V-Lithium battery, installed.
• Two drywall anchors.
• Two mounting screws.
2 Installation and Startup
2.1 Installation Notes
• These products are designed to be maintained by professional 
security technicians.
• Products are tested for indoor use.
• All products should be manually tested semi-annually.
2.2 Activate the Battery
1. Twist the detector counterclockwise and lift it off of the mounting base. 
2. Remove the tag in the battery compartment to connect the battery.
3. Ensure the battery is seated.
Part #
Check-In
Location
EN1245
3 minutes
North America
EN1245-60
60 minutes
North America
EN1245A
3 minutes
Australia
EN1245Z
3 minutes
New Zealand
End 
Devices
Maximum 
Repeaters
150
397
250
386
350
375
500
360
1000
313
2000
238
3000
184
For product and installation videos visit us at 
www.inovonics.com/videos or use the QR 
code below.
Green LED
Red LED
Sounder
Normal 
(standby)
Blinks every 
10 seconds
Off
Off
Alarm/test
Off
Blinks 
every one 
second
Temporal 4 pattern: 
Four short beeps 
followed by a five 
second pause. If 
conditions return to 
normal, the detector 
self-restores out of 
alarm.
Low battery
Off
Blinks 
every 45 
seconds for 
37 days
Chirps every 45 
seconds beginning 
seven days after the 
LED begins blinking; 
continues for 30 days
Detector trouble
Off
Blinks 
every five 
seconds
Chirps every 45 
seconds
Detector end-of-
life
Off
Blinks 
every 10 
seconds
Chirps every 45 
seconds
Power up
LED blinks 
every ten 
seconds for a 
total of four 
times
LED blinks 
every ten 
seconds for 
a total of 
four times
Off
Test 
button
Green 
LED
Red 
LED