Inovonics Wireless Corporation 3B6OT9PMX User Manual

Page of 2
© Inovonics, 2011 - www.inovonics.com
EN1501/EN1501-XL EchoStream
®
 TapWatch
®
 
Transmitter
Installation and Operation Manual - 04590F
1 Overview
Connected to pulse-output meters being used for multi-family submetering, 
the EN1501 and EN1501-XL transmitters will transmit data to an RF 
receiver that is connected to a Data Concentrator and Communicator 
(DCC-5800). The EN1501 includes a replaceable battery; the EN1501-XL 
includes a long-life battery that is not replaceable.
1.1 Inovonics Wireless Contact Information
If you have any problems with this procedure, contact Inovonics Wireless 
technical services:
• E-mail: support@inovonics.com
• Phone: (800) 782-2709; (303) 939-9336
1.2 EN1501/EN1501-XL Components
 Figure 1  EN1501/EN1501-XL Components
2 Installation and Startup
2.1 Connect Transmitter to Meter
Connect the transmitter to the meter as follows:
1. Open the housing by pressing down on the base tab near the wiring 
thru-hole while lifting away the cover. 
2. Fully insert stripped wires into the removable header terminal.
3. Use a small Phillips screwdriver to tighten the screws that secure wires 
to the removable header terminal.
4. Attach removable header terminal (if removed) to the transmitter board 
as shown.
Note: If connecting to a meter that has polarity to its pulse output, the 
negative (–) should be connected to the outside terminal, closest to the 
corner of the board.
 Figure 2  Connect the Transmitter to the Meter
2.2 Select Frequency Band
If you are using either transmitter anywhere except North America, you will 
need to select the frequency band for your geographic area. If you are 
using the transmitter in North America, there is no need to select the 
frequency band. All transmitters are set for North America by default.
Select Frequency Band on the Transmitter
1. Place the selection jumper included in the accessory pack on the 
appropriate frequency band selection pins (Figure 1).
• Leave the jumper off the pins to select 902-928 MHz for North 
America.
• Place the jumper on the left two pins to select 921-928 MHz for New 
Zealand.
• Place the jumper on the right two pins to select 915-928 MHz for 
Australia.
2.3 Mount the Transmitter
1. Use the double-sided tape to mount the transmitter to a clean wall.
2. If installing the EN1501, the transmitter can be secured a wall with the 
mounting screw and anchor. Remove the battery to access the 
mounting screw hole; press the reset button after replacing the battery.
Note: Ensure cabling enters the housing through the access wiring thru-
hole, and replace the housing (Figure 2).
 Figure 3  Mount the Transmitter
2.4 Register the Transmitter
Note: See “Programming the PMT-Meter Pair” in TapWatch User Manual 
for more information.
1. Confirm that transmitter is connected to the meter.
2. Confirm that the battery is installed.
3. Go to the “Registered Meters” tab of the Site Information editor.
4. Click “Add” on the “Registered Meters” page; confirm selected building.
5. Complete the “Add New Meter To...” form when it appears. 
6. Click the “Register” button.
7. When prompted, press the reset button on the transmitter; wait for 
confirmation.
Battery (EN1501-
style battery shown)
Tamper switch
Frequency band 
selection pins
Removable header 
terminal
Reset button
C
A
B
D
E
Cabling thru-hole
Removable header terminal
Anchor installed in wall
Double-sided tape
Mounting screw
A
B
A
B
C