Xmark Corporation EAC User Manual

Page of 3
EAC Transceiver:  
Installation Guide
 
981-000046-000R1.05 
 
 
CONNECTIONS 
 
 
 
 
 
 
 
 
 
                 
NO
USER DEFINED
RELAY CONTACTS
GND
LISTED CAT 5E
FROM DOOR SWITC
COM
3A/30VDC RESITIVE
EAC TRANSCEIVER
24VDC 300MA
250VA PWR LIMITED
SELV SUPPLY
NOTE: 307.2 kHz EXCITER
INDUCTORS MOUNTED 
ON PC BOARD
GND
1
2
3
4
5
6
7
8
RS485 +
433.92 MHz RECEIVE
ANTENNA
RS485 -
DOOR SW
RS485 NETWORK
+Vin
 
 
 
 
 
eAC System components are designed to meet the requirements for Class 2 circuits operating from a 
non-hazardous secondary power source limited to 240 VA.  Cabling materials must be selected for the 
installation environment in accordance with the applicable jurisdictional codes.   
 
 
 
 
INSTALLATION 
 
 
 
MOUNTING INSTRUCTIONS 
 
The Controller chassis may be horizontally or vertically mounted on a wall, ceiling, or shelf as long as the 
front face panel is easily accessible. The RX antenna should be positioned on a vertical plane for 
maximum performance.  
The detection field radiates from two internal orthogonal ferrite cored inductors. The field must fill the 
area in front of the door all the way to the floor so that no Tag can reach the door without being detected. 
 
SATELLITE EXTENSION 
1 2 3 NOT USED ON 
THIS PRODUCT