OPTI DS1000B Leaflet

Page of 2
CS730B
33.
DS1000B/ DS1500B/ DS2000B/ DS3000B
Durable Series
For data centers and mission
critical systems
Specifications
Model Name
DS1000B
DS1500B
DS2000B
DS3000B
Topology
On-battery Output Waveform
Maximum Capacity
1000VA / 700W
1500VA / 1050W
2000VA / 1400W
3000VA / 2100W
INPUT
Number of Phase
Nominal Input Voltage
Input Voltage Regulation
Nominal Input Frequency
Input PFC
Input Short Protection
OUTPUT
Nominal Output Voltage
Output Voltage Regulation (battery mode)
Output T.H.D
High Efficiency Mode (AC to AC)
Crest Factor
Start on Battery
Auto Restart
Number of Outlets
PROTECTION
Data Line Surge Protection
Surge Energy Rating
Overload Protection
Short Circuit Protection
BATTERY
User Replaceable Battery
DC36V / 12V 7.2Ah × 3 DC36V / 12V 34W × 3 DC72V / 12V 7.2Ah × 6 DC72V / 12V 34W × 6
Typical Backup Time (Full / Half load)*
6 / 18 min
5 / 15 min
6 / 18 min
5 / 15 min
Recharge Time to 90% (Typical)
BP1000
BP1500
BP2000
BP3000
12V 7.2Ah × 6
12V 34W × 6
12V 7.2Ah × 12
12V 34W × 12
ADVANCED WARNINGS / DIAGNOSTICS
Front Panel LEDs
Audible Alarms
COMMUNICATION INTERFACE
Communication Port
SNMP Manageable 
ENVIRONMENTAL
Operation Temperature
Storage Temperature
Relative Humidity
Audible Noise
PHYSICAL
Dimensions (Physical / Packing)                 (in)
(LxWxH)                                                   (mm)
Weight (Net / Gross)                                 (lbs)   
                                                                   (kg)
36.4 / 40.6
16.5 / 18.4
37.7 / 41.9
17.1 / 19
68.5 / 74.1
31.1 / 33.6
72.8 / 78.3
33 / 35.5
Battery Pack Dimensions                            (in)
(Physical / Packing) (LxWxH)                  (mm)
Battery Pack (Net / Gross)                        (lbs)
                                                                   (kg)
CONFORMANCE
Approvals
Specifications are subject to change without notices.
* Typical backup time depends on power consumption of equipment attached and on UPS battery capacity. Values here are for reference only.
** The external battery pack is optional. Battery pack needs to be connected to UPS before connecting any load and turning on the UPS.
# The model with optional USB port provides both RS232 and USB connectivity, but only one connectivity can be used at the same time.
16.5×8.9 ×14.1 / 20.7×13.8×19.1
420×225×358 / 526×350×485
Extended Battery Pack (Optional)**
 4 Hours
AC mode / On line / On battery / Bypass / Fault / Overload and 15 UPS Parameters
-20~60°C / -4~140°F
Battery mode / UPS faults / Overload
RS232 and USB
#
Yes
0~40°C / 32~104°F
125 Joules(100/110/120Vac) ; 280 Joules(220/230/240Vac)
 125% Load for 1 minutes 150% of 10 seconds(on line),
130% Load for 10 seconds >130% of 1.5 seconds (on-battery)
0~95% humidity, non-condensing
UL / cUL(1X0V) ; CE , A-Tick , C-Tick , GOST-R(2X0V)
<40dBA (at 1 meter from surface of unit)
16.5×8.9 ×14.1 / 20.7×13.8×19.1
420×225×358 / 526×350×485
16.5×6×9.4 / 21.5×11×14
420×152×238 / 545×280×355
46.7 / 50
21.1 / 22.6
88.4 / 98.4
40 / 44.5
16.5×6×9.4 / 21.5×11×14
420×152×238 / 545×280×355
UPS output cut off immediately
6 Battery backup (US)
4 Battery backup (IEC)
12 Battery backup (US)
Rated Voltage +/-2%
 3% T.H.D at Linear Load
3 : 1
Yes
92%
Yes
RJ11 / RJ45
True On-Line, Double Conversion
Sine Wave 
Single Phase (2W+G)
100/110/120/127Vac or 220/230/240Vac (selectable)
80-144Vac(100/110/120Vac) or 160-276Vac(220/230/240Vac)
50Hz / 60Hz Auto Sensing 
Circuit Breaker
 0.97@Full load
100/110/120Vac or 220/230/240Vac
Sine Wave
9 Battery backup (IEC320 10A×8, IEC320 16Ax1)
Line Interactive
UPS Series
On-Line UPS
Series
Stabilizer
 Series
Networking
Series
Inverter Series Surge Series  Power Storage
 Series
Standby UPS
Series