Interactive pen display
TESTING YOUR PEN
If the pen does not work as you expect, it is a good idea to first check the assigned functions or reset the 
pen to its default conditions.  A quick way to reset a pen to its default settings is to remove it from the T
OOL
 
list by clicking on the list’s [ – ] button.  After the pen has been removed, place it back onto the display 
screen surface and the pen will be re-added to the T
OOL
 list with its default settings.
Open the Wacom Tablet control panel and click on the A
BOUT
 button.  In the dialog box that appears, click 
on the D
IAGNOSE
... button to open the D
IAGNOSTICS
 dialog box.  The D
IAGNOSTICS
 dialog box displays 
dynamic information about the interactive pen display and pen.  This information is used when testing the 
pen display and your pen.
If more than one pen display unit is connected to your system, be sure to select the unit for which you are 
testing in the T
ABLET
 I
NFO
 column.
Note:  When testing your pen buttons, if a button is set to R
ADIAL
 M
ENU
 or O
PEN
/R
UN
..., that function will 
occur when the button is pressed.  In this case you may want to change that button’s function 
before testing.
1. While observing the P
OINTING
 D
EVICE
 I
NFO
 column, bring your pen within 5 mm (0.2 inch) of the display 
screen.  A value for P
ROXIMITY
, the D
EVICE
 N
AME
, and D
EVICE
 T
YPE
 should be displayed.
2. Move your tool along the pen display screen surface.  The X and Y Data values should change to reflect 
the tool position.
3. Test your pen switches.  The pen display status LED should light blue each time you click with the pen 
tip, press the side switch, or press the pen eraser to the display screen.
Press on the display screen surface with the pen tip.  The S
WITCHES
 state and P
RESSURE
 value 
should change.  (P
RESSURE
 should change from approximately 0% with no pressure applied to 
approximately 100% when full pressure is applied.)
Next, press the side switch without pressing the tip to the display screen surface.  The S
WITCHES
 
state should change.  Do this for both positions of the DuoSwitch. 
Press the pen eraser to the display screen.  The S
WITCHES
 state and P
RESSURE
 value should change.  
(P
RESSURE
 should change from approximately 0% with no pressure applied to approximately 100% 
when full pressure is applied.)
4. When you are done, click on the C
LOSE
 button to exit the dialog box.
Tip = 1, DuoSwitch (lower position) = 2, DuoSwitch (upper position) = 3, Eraser = 1