Routine Maintenance
Replace Fuse
R110/R170XiIIIPlus User Guide 
117
Replace Fuse
The fuse is user-replaceable in the R170XiIIIPlus printer. The R110XiIIIPlus fuse must be 
replaced only by an authorized service technician. 
The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry 
module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is 
provided as a spare. The end caps of the fuse must bear the certification mark of a known 
international safety organization. 
To replace a faulty fuse, complete these steps:
1. Use a small-blade screwdriver or similar tool to remove the fuse holder. 
The fuse holder is part of the AC power entry module at the rear of the printer. This 
illustration identifies the parts of the AC power entry module. 
2. Remove the faulty fuse and install a new fuse in the in-circuit position as shown. 
This illustration identifies the parts of the fuse holder.
Caution • Turn the AC power switch Off (
O
) and remove the power cord before performing 
this procedure.
1
Power switch
2
Fuse holder
3
AC power entry module
4
Small-blade screwdriver
Important •  If you use the spare fuse, be sure to order a replacement fuse from your 
authorized Zebra distributor. The spare fuse should be the exact type and rating as the 
original in-circuit fuse.