Integrated Microwave Technologies LLC. 23VT2-P10 User Manual

Page of 72
NewsCaster VT2 
 
Installation 
 
M17-0002-01A Rev 0.0 
38 
 
User Manual 
Config Type  Control Unit Connector 
Cable Type 
# of 
Conductors 
Cable Use 
RF Head Connector 
Standard 
Coax 
(w/o P&T) 
TNC Connector 
Trompeter UPL40-41 
Nucomm 511-F3003-000
 
Belden 1694A 
RG-6U 
(recommended
N/A
 
•  70 MHz IF 
•  Inter-Unit Data 
•  +48 VDC Power 
TNC Connector 
Trompeter UPL40-41 
Nucomm 511-F3003-000
 
 
 
 
 
 
 
TNC Connector 
Trompeter UPL40-41 
Nucomm 511-F3003-000 
Belden 1694A 
RG-6U 
(recommended
N/A 
•  70 MHz IF 
•  Inter-Unit Data 
•  +48 VDC Power 
TNC Connector 
Trompeter UPL40-41 
Nucomm 511-F3003-000 
Standard 
Coax 
(w/ P&T 
Pan & Tilt Power 
#18 AWG 
•  120 VDC 
7-Pin Connector 
Nucomm 512-F3003-070 
 
 
 
 
 
 
Standard 
Triax 
(w/o P&T) 
Triax Connector 
Trompeter PL375-13A 
Nucomm 511-F3002-000
 
Belden 8232A 
RG-59U 
(recommended
N/A
 
•  70MHz IF 
•  Inter-Unit Data 
•  +48 VDC Power 
Triax Connector 
Trompeter PL375-13A 
Nucomm 511-F3002-000
 
 
 
 
 
 
 
Triax Connector 
Trompeter PL375-13A 
Nucomm 511-F3002-000 
Belden 8232A 
RG-59U 
(recommended
N/A 
•  70MHz IF 
•  Inter-Unit Data 
•  +48 VDC Power 
Triax Connector 
Trompeter PL375-13A 
Nucomm 511-F3002-000
 
Standard 
Triax 
(w/ P&T) 
Pan & Tilt Power 
#18 AWG 
•  120 VDC 
7-Pin Connector 
Nucomm 512-F3003-070 
 
 
 
 
 
 
TNC Connector 
Trompeter UPL40-41 
Nucomm 511-F3003-000 
Belden 1505 
(e.g.) RG-59U 
N/A
 
•  70 MHz IF 
•  Inter-Unit Data 
TNC Connector 
Trompeter UPL40-41 
Nucomm 511-F3003-000 
Alternate 
Coax 
(requires 
Aux Power 
Option) 
(w/o P&T) 
Terminal Strip 
Nucomm 514-E0003-04A 
#20 AWG 
•  +48VDC Power 
15-pin connector 
ITT Cannon: MS3116J14 
Nucomm 512-F3012-015 
 
 
 
 
 
 
TNC Connector 
Trompeter UPL40-41 
Nucomm 511-F3003-000 
Belden 1505 
(e.g.) RG-59U 
N/A 
•  70 MHz IF 
•  Inter-Unit Data 
TNC Connector 
Trompeter UPL40-41 
Nucomm 511-F3003-000 
Aux Power Cable 
#20 AWG 
•  +48 VDC Power 
15-pin connector 
ITT Cannon: MS3116J14 
Nucomm 512-F3012-015 
Alternate 
Coax 
(requires 
Aux Power 
Option) 
(w/ P&T) 
Pan & Tilt Power 
#18 AWG 
•  120 VDC 
7-Pin Connector 
Nucomm 512-F3003-070 
Table 7: Typical IF cable configurations for the NewsCaster VT2  
 
 
Control Unit 
“AUX Power” 
Function 
Recommended 
Wire Size 
RF Head 
“AUX DC POWER” 
+48 VDC 
#18 Violet 
+48 VDC 
#18 Violet 
Ground 
#18 Black 