Motorola Mobility LLC T56KT1 User Manual
Controls and Indicators Interface
46
G30 - Module Hardware Description
December 15, 2009
In case the serial interface incorporates hardware flow control signals, the data will be sent
according to their state, after the ATS102 delay time has expired.
according to their state, after the ATS102 delay time has expired.
•
ATS100 - Defines the application minimal wakeup duration, in seconds, for a single wakeup
event. This time definition is required to avoid frequent unnecessary wakeup events and
consequent ATS102 delays.
The application may return to low power mode after the serial interface has been inactive for
the duration set by ATS100. This duration is measured from the last data sent or received on
the serial interface.
event. This time definition is required to avoid frequent unnecessary wakeup events and
consequent ATS102 delays.
The application may return to low power mode after the serial interface has been inactive for
the duration set by ATS100. This duration is measured from the last data sent or received on
the serial interface.
Figure 2-21: WKUPO Operation
The following guidelines apply to the wakeup-out mechanism:
•
G30 will set the WKUPO signal low to indicate that in has data to send through the serial
interface.
interface.
•
G30 will start sending the data to the application after the delay defined by ATS102.
•
The WKUPO signal will remain low while data is being sent to the host application.
•
The host application should keep its serial interface active, and not switch to low power
mode, while the WKUPO signal is low.
mode, while the WKUPO signal is low.
•
G30 will set the WKUPO signal high when it has completed sending the data.
•
The application serial interface must stay active, and not switch to low power mode, for the
duration set by ATS100, after WKUPO is set high.
duration set by ATS100, after WKUPO is set high.
•
G30 will not set the WKUPO signal low if it needs to send additional data during the
ATS100 delay time.
ATS100 delay time.
•
The application may switch to low power mode after the WKUPO signal is set high and the
serial interface has been inactive for the duration set by ATS100.
serial interface has been inactive for the duration set by ATS100.
Antenna Detection
The G30 incorporates an internal antenna detection circuit, which senses the physical connection
and removal of an antenna or antenna circuit on the G30 antenna connector. The antenna
detection state is reported to the application through the ANT_DET output signal, and may also
be queried by the ATS97 command.
and removal of an antenna or antenna circuit on the G30 antenna connector. The antenna
detection state is reported to the application through the ANT_DET output signal, and may also
be queried by the ATS97 command.
The detection circuit senses DC resistance to ground on the G30 antenna connector.