Remote Keyless Entry System Specification 
Spec. No. 
DPE-AE-RK019912S 
Written by  
Ban Dong Hoon 
Rev. No.  
A0 
Date 10
th
 . Nov. 2003 
Page 
10 / 25
 
 
 
If the above theft detection input is received at the arming mode, the type of theft is memorized at 
the Rx EEPROM. But the alarm duration is not prolonged even if theft detection signal is 
recognized during the alarm mode. That is, the Rx ignores the theft detection input until the 
alarm is finished. 
 
During the alarm is activated, if the “lock” , “unlock”, “door” function code is received, the Rx 
performs the function according to be received code and the burglar alarm (audible alarm and 
visible alarm) is deactivated. If the “trunk” function code is received, the Rx does not perform the 
function and the burglar alarm is deactivated. And if the tamper switch (passenger unlock 
disarming / driver unlock disarming / trunk unlock disarming) is ON, the Rx stops the burglar 
alarm and goes to the disarming mode. 
 
 
 
              TIME   sec 
 
 
   OUTPUT           0        0.25      0.5       0.75                     27       27.25     27.5       27.75        28 
 
     SIREN 
 
     
   HAZARD    
      LAMP 
[Figure 3. Timing Chart for Burglar Alarm] 
 
3.3   
DISARMING BY KEY CYLINDER 
If the tamper switch (passenger unlock disarming / driver unlock disarming / trunk unlock 
disarming) is ON, the Rx stops the burglar alarm and goes to the disarming mode.