Deister Electronic GmbH AMANTAGCOMPACT User Manual

Page of 16
ST1 (PRX)
P1
beeper–input
P2
ground
P3
positive currant voltage 24V  (18V – 30V)
P4
Wiegand-output D1 ( loading arrangement RS 232 )
P5
Wiegand-output D0
P6
Wiegand-output CP
P7
LED green input
P8
LED red input
P9
RS485 - A
P10
RS485 - B
P11
Tamper-contact
P12
Tamper-contact
ST2 (SATELLITE)
P1
positive currant voltage, 24V (18V ... 30V)
P2
ground
P3
RS485 - A
P4
RS485 – B
ST3 (SYNC)
P1
positive currant voltage, 24V (18V ... 30V) 
P2
ground
P3
SYNC - A
P4
SYNC – B
P5
SYNC-AIN
P6
SYNC-BIN
ST4 (RELAYS 1)
P1
connected to P2, in case yellow LED is turned off (Breakdown of 
current voltage or alarm-condition)
P2
reference connection of the relays
P3
connected to P2, in case the yellow LED is turned on
ST5 (RELAYS 2)
P1
connected to P2, in case the red LED is turned off
P2
reference connection of the relays
P3
connected to P2, in case the red LED is turned on (alarm-condition)
8
deister electronic GmbH  30890 Barsinghausen  Germany
 V04/09/07
amanTag compact