Selex Sistemi Integrati Inc. VOR2 User Manual

Page of 254
Model 1150A DVOR 
 
3-64 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
Figure 3-61 LCU Transmitter Temperature Readings 
 
Table 3-5 Equipment Control Panel Functions (Refer to 
)
TRANSMITTER 
(Refer to 
)
Note: Switches are active in Local Mode only. 
Main Select 1 and Indicator 
Pressing  Main  Select  1  switch  sets  transmitter  1  as  the 
main  transmitter  and  places  TX1  on  the  antenna  and  in 
the ON  mode. The indicator in the  switch illuminates to 
identify that TX 1 is selected as the Main. 
Main Select 2 and Indicator 
Pressing  Main  Select  2  switch  sets  transmitter  2  as  the 
main  transmitter  and  places  TX2  on  the  antenna  and  in 
the ON  mode. The indicator in the  switch illuminates to 
identify that TX 2 is selected as the Main. 
Antenna 1 and Indicator 
Pressing  Antenna  1  switch  turns  transmitter  1  ON  and 
into  the  antenna.  The  indicator  in  the  switch  illuminates 
to identify the transmitter connected to the antenna. 
Antenna 2 and Indicator 
Pressing  Antenna  2  switch  turns  transmitter  2  ON  and 
into  the  antenna.  The  indicator  in  the  switch  illuminates 
to identify the transmitter connected to the antenna. 
Load 1  and Indicator 
Pressing  Load  1  switch  turns  transmitter  1  ON  and  into 
the  load.    The  indicator  in  the  switch  illuminates  to 
identify the transmitter connected to the load. 
Load 2  and Indicator 
Pressing  Load  2  switch  turns  transmitter  2  ON  and  into 
the  load.    The  indicator  in  the  switch  illuminates  to 
identify the transmitter connected to the load. 
Off 1 and Indicator 
Pressing  Off  1  switch  places  transmitter  1  in  the  OFF 
mode  without  changing  the  relays.    The  indicator  in  the 
switch illuminates when the transmitter is OFF. 
Off 2 and Indicator 
Pressing  Off  2  switch  places  transmitter  2  in  the  OFF 
mode  without  changing  the  relays.    The  indicator  in  the 
switch illuminates when the transmitter is OFF.