Selex Sistemi Integrati Inc. VOR2 User Manual

Page of 254
Model 1150A DVOR 
 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
1-3
1.2.1.1 Local Control Unit (LCU) (1A1)
The  Local  Control  Unit  (LCU)  is  located  in  the  upper  portion  of  the  VOR  cabinet  and  provides  station  status 
information.    The  LCU  provides  for  Transmitter,  Monitor  and  System  setup,  monitoring  and  control.  Alarm 
indication from the VOR Monitors initiates transfer or VOR shutdown. 
 
1.2.1.2 Synthesizer Assembly (1A3A1, 1A3A11)
The Synthesizer assembly generates three RF signals (carrier, upper and lower sidebands) for the VOR transmitter.  
There  are  three  boards  in  the  Synthesizer  Assembly.  The  Carrier  board  provides  the  carrier  frequency  and  phase 
control capability for the Carrier Amplifier. The sideband board generates upper and lower sideband frequencies for 
the Sideband Amplifier Assemblies. The third board (Interface) provides connectivity to the backplane and includes 
digital interface circuitry to the Audio Generator and RMS processors.
 
1.2.1.3 Audio Generator CCA (1A3A2, 1A3A9)
The  Audio  Generator  CCA  is  responsible  for  developing  and  controlling  the  audio  signals,  generating  the  carrier 
modulation signals and monitoring and controlling RF power level and phase control signals used in the DVOR.  In 
addition,  DC  analog  voltages  representing  different  modulation  and  power  levels  of  the  DVOR  RF  signals  are 
applied  to,  and  analyzed  by,  the  audio  generator  to  determine  carrier  power  levels,  carrier  percent  modulation, 
sideband power levels and VSWR.  An on-board micro controller and memory circuitry controls all functions within 
the CCA and communication through the serial connection to the RMS CCA.