Selex Sistemi Integrati Inc. VOR2 User Manual

Page of 254
Model 1150A DVOR 
 
2-2 
Rev. -  November, 2008 
 
This document contains proprietary information and such information may not be disclosed 
to others for any purposes without written permission from SELEX Sistemi Integrati Inc. 
Figure 2-1  RF Spectrum of a Doppler VOR 
 
The deviation frequency is determined by the formula: 
 
x
x
=
f
d
Where: 
f
d
equals the deviation frequency in hertz. 
 
W equals the angular velocity of the signal (30 Hz). 
 
X equals the diameter of the ring in wavelengths. 
 
Y equals 3.14. 
 
30
f
=
r
d
d
In the aircraft receiver, a 30 Hz signal is extracted from the 9960 Hz FM subcarrier.  The phase of this second 30 Hz 
signal  varies  linearly  with  the  change  of  the  azimuth  bearing  of  the  receiving  point;  for  each  degree  of  azimuth 
change, the phase of the 30 Hz variable phase signal changes by one degree.