3.1.4  Reader Output Interface and Pull-up Resistors 
The SmartID readers provide true open collector outputs for Wiegand, Clock-and-
Data, ABA track 2 emulation, meaning the data output is not voltage driven. 
External pull-up resistors are required when the controller does not provide internal 
pull-up resistors. The typical value for the pull-up resistors is 1kOhm. The 
recommended position to place the pull-up resistors is at the controller side. 
The pull-up resistor #1 connects form Data/D1 (reader connector pin 3) to a 5 volt 
reference. 
The pull-up resistor #2 connects form Clock/D0 (reader connector pin 4) to a 5 volt 
reference. 
February 13, 2008 
 
© 2008 HID Global Corporation.  All rights rese
 
SmartID Proximity Reader - 8030-901, Rev A.0 
 
5.3  Tamper Switch - Optional 
Figure 2 Tamper Switch