Selecting the Calibrate Laminator tab  
The Calibrate Laminator tab is active when the Laminator is automatically detected or when the 
Laminator is manually checked (as a Printer Feature on the Configuration tab). If the Laminator is not 
detected and not manually checked, the tab is active; however, all functions are grayed out. 
•  Calibrate button:  Sends calibrate Laminator command to Printer. Follow the instruction on the page 
for setting up the Printer.  
•  Help button:  Launches help specific to this tab.  
Step Procedure 
Select the Calibrate Laminator tab. 
a.  Ensure that the Cartridges are out of the Laminator. 
b.  Ensure the Laminator Cover is closed. 
c.  Click on the Calibrate button. (Note:  The Printer’s LCD will display 
CALIBRATE PASSED. Error Message Calibration Failed may be 
solved by manually increasing the sensor calibration number to 13 of 
higher under the Advanced Settings tab. Do not use the AUTO calibrate 
function.)   
d.  Click on the OK button on the LCD display to complete the procedure. 
 