 Multi-Protocol Reader Ver. 2: Maintenance Instructions 
 
Confidential 
UM 360450-210: A7 
Page 177 of 282 
© Kapsch TrafficCom Canada Inc. 2013 
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom  Canada Inc. and are issued in strict 
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or 
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc. 
 
 
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX 
 
10/31/2013 7:56 
Kapsch TrafficCom 
2.  Click the 
Channel tab. 
Result: The following screen appears. 
 
3.  Set the  
Dynamic Voting Control to Reader to allow the Reader to automatically set the voting time by 
calculating the average capture zone span time.  
4.  Press 
Enter.  
5.  Enter a sample size in the 
Dynamic Voting Sample Size field. This is the number of previous transactions 
the Reader includes when calculating the average capture zone span time. 
Note: The Reader calculates the capture zone span time after each OBU transaction. The Reader will not 
update the Dynamic Voting Time unless the capture zone span time changes more than the Dynamic Voting 
Threshold percentage. 
6.  Enter a percentage in the 
Dynamic Voting Threshold field.  
7.  Press 
Enter or click outside the fields.  
Result: The following screen appears.