LED Statuses 
The following table gives an overview of all the LEDs on the Reader. See the Troubleshooting Trees 
beginning on page 186 to resolve any issues. 
Table 6-1: CTM LED states explained 
CTM LEDs 
LED 
State 
Meaning 
CGC 
solid green 
CGC is functional 
solid red 
CGC has failed 
MC 
solid green 
MC is functional 
solid red 
MC has failed 
SYNC 
solid green 
Reader is synchronized 
flashing red 
Reader out of sync, or, 
No activity on the Rx port on the terminal block of the 
SPM (R+ and R- on the connector). 
another Reader in sync network is stuck in the busy 
state 
flashing green/orange 
Reader is out of sync and attempting recovery 
off 
Synchronization is disabled 
ACTIVE 
solid green  
the CTM is active and in control. This indicates if the 
primary or secondary side is active.  
solid red 
the CTM is not active 
POWER 
solid green 
CTM is receiving power from PSM 
off 
CTM is not receiving power from PSM, or,  
CTM reset switch is OFF 
ACTIVITY 
(Ethernet 1) 
flashing green 
data is being transmitted via the Ethernet 1 port 
off 
data is not being transmitted via the Ethernet 1 port 
ACTIVITY 
(Ethernet 2) 
flashing green 
data is being transmitted via the Ethernet 2 port 
off 
data is not being transmitted via the Ethernet 2 port